Sustainable Building Solutions logo

Sustainable Building Solutions

For sales enquiries
0844 822 0700
Sustainable Building Helpline
0800 688 8388
Product Name

Kaflex

Product Type

Air Tightness - grommet for cables and small pipes

Product Spec Sheet
  • Energy saving
  • Healthy
Product Name

Description

Top

If pipes or cables penetrate the air tightness layer, they must be securely sealed. The most suitable means of doing this is with air tightness grommets made from EPDM. This flexible material allows a tight fit, and Kaflex allows for a secure feed-through for cables and pipes. Kaflex cable grommets feature an integrated adhesive with a release paper for ease of application.

• For an airtight seal around pipes and cables which pass through the INTELLO PLUS or DB+ membrane. They are made of non-ageing elastic EPDM rubber in a high adhesive square

• With Release paper

• Offers high protection against piercing due to its high elasticity

Related product Intello Plus

Product Code

788612 Kaflex Mono Cable Grommet - Single 6-12mm – 145mm x 145mm

788613 Kaflex Mono Cable Grommet – Twin 6-12mm – 145mm x 145mm

788614 Kaflex Mono Cable Grommet – Multi 6-12mm – 140mm x 140mm

Manufacturer

Top
Name:
Ecological Building Systems UK Ltd / pro clima UK
Address:
Ecological Building Systems UK Ltd Pacific House Parkhouse Carlisle Cumbria CA3 0LJ
Telephone:
+44 5600 758025
Email:

info@ecologicalbuildingsystems.com

Website:

http://www.ecologicalbuildingsystems.com/

More information

Brands

Products are available from these brands:

  • Main_brand-logo-ccf
  • Main_brand-logo-keyline
  • Main_brand-logo-tp
  • Main_brand-logo-bss

To purchase this product either:

  • Call Sustainable Building Solutions on 0844 822 0700

  • Or visit your local branch

Technical Details

• Material EPDM acrylate solvent free adhesive tape

• Temperature Resistance - 40C to 100C

• Grommet Sizes Single Cable – for cable diameters between 6mm – 12mm – 145mm x 145mm

• Kalflex Duo – Twin Cable – for cable diameters between 6mm – 12mm – 145mm x 145mm

• Kaflex Multi – for cable diameters between 6mm – 12mm – 140mm x 140mm

• 3rd party accreditation IAB

• Life Expectancy 60 years+

• Usage Interior and Exterior

Current UK and IRISH Building Regulations and Method of Measurement

The most commonly used unit of measurement for airtightness in Ireland and the UK is referred to as the air permeability of a building or Q50.

To measure air permeability a pressure differential is induced onto a building using a large fan called a Blower Door. An air tightness measurement usually involves a combination of depressurising and pressuring a building to a pressure difference of 50 Pascal’s (50Pa) which is equivalent to a wind speed of about 20 miles per hour on every side of the building envelope at once, by no means an extreme pressure. Once the pressure differential reaches 50Pa, air leakage may easily be located in the external envelope and an accurate measurement of the air permeability of the external envelope of the building is taken.

The air permeability of a building at a pressure differential of 50Pa is referred to as the Q50 of a building and is measured in m3/hr (of airflow) per m² (of total external envelope area).